www.watermeters.com.au
Installation Rules and Tips: 1.
As a general rule, all water meters should be
installed in such a way as to minimize water turbulence inside the meter and
this is achieved by installing the meter with lengths of straight pipe before
and after the meter. Again as a general rule, 10 x the diameter of straight
pipe before and, 5 x the diameter of straight pipe after the meter. So for a
100mm water meter you should have 1m of straight pipe before the meter and 50cm
of straight pipe after the meter. 2. Some meters are
suitable for installation in horizontal, vertical or inclined positions and this
makes it easy. Some however must only be installed in a horizontal
position and this really is important as they are not designed for other
installations and will not operate correctly or will fail. Warranty
does not cover incorrect installations. 3. When a meter is to
be installed the supply line to the meter must be flushed to remove any debris.
If this is not practical then a filter of suitable size must be installed
upstream of the meter and the filter must be cleaned regularly. 4. All meters must be
installed with the register uppermost.
|